Description Class HallwaySection

INTENTION

This class provides all definitions to describe the hallway specific light requirements. Each hallway section is equipped with

Note that there are no requirements concerning the temperature in a hallway.

REQUIREMENT SPECIFICATIONS

Property  R_HS1 
NL : Whenever a person is continuously in the near of a hallway door of the hallway section for at least T_HS1 time units indicating that he wants to enter the hallway section, then the light in the hallway section will be on within this time span, and remains on at least as long as the person is near the hallway section.

Property  R_HS2 
NL : Whenever the lights are neither controllable automatically nor manually for at least T_HS2 time units, then eventually within this time span, the light in the hallway section is on and remains so at least as long as the lights are neither controllable automatically nor manually.

MACHINE SPECIFICATIONS

Property  M_HS1 
NL : The value of $T\_ \mathit{HS}_1$ is always 50 milliseconds.

Property  M_HS2 
NL : Whenever the light is not controlled manually the light intensity in a hallway section that is occupied has to be greater than or equal to the light intensity needed to establish save light.

Property  M_HS3 
NL : The machine always assumes that there is currently no person in a hallway section iff the values of all three motion detectors are 0.