next up previous contents index FOREST_HomepageFOREST_Example_Homepage
Next: Description Class BinarySensor Up: No Title Previous: Description Class Sensor

   
Description Class OutdoorLightSensor

INTENTION

This class provides all definitions to describe the behavior of a outdoor light sensor. This class is derived from the description class Sensor. The following specific parameters of a outdoor light sensor are instantiated:

Both functions, modifyReaction and modifyConversion, have still to be provided by the domain expert.

DOMAIN KNOWLEDGE

Property  D_OLS1 
NL : The conversion time of an outdoor light sensor is 1 second.

Property  D_OLS2 
NL : The reaction time of a outdoor light sensor is 10 milliseconds.

REQUIREMENT SPECIFICATIONS

Property  R_OLS1 
NL : The value of the sensor determined automatically in the case of a malfunction of the outdoor light sensor corresponds with the last correctly measured value.


next up previous contents index FOREST_HomepageFOREST_Example_Homepage
Next: Description Class BinarySensor Up: No Title Previous: Description Class Sensor